List of Measures for the Local Insulation Initiative Grant Program

Version 1: For Owner-Occupied Homes

(Last updated: August 2026)

1

Energy-saving measure

Minimum number ofsquare meters Minimum Rd value or maximum U-value*Comments
2

Cavity wall insulation

10m²

Rd value ≥ 1.1m² K/W
3

Façade insulation

10m²

Rd value ≥ 3.5m² K/WThis applies to the interior or exterior of the facade. You will not receive a grant for interior walls or partition walls.
4

Roof insulation

20m²

Rd value ≥ 3.5m² K/W
5

Attic/Loft Floor Insulation

20m²

Rd value ≥ 3.5m² K/W
6

Floor Insulation

20m²

Rd value ≥ 3.5m² K/W
7

Floor Insulation

20m²

Rd or Rbf ≥ 3.5 m²K/W
8

HR++ glass

3m²

U-value ≤ 1.2 W/m²K
9

Triple-pane glass

U-value ≤ 0.7 W/m²K
10

Vacuum Glass

U-value ≤ 0.7 W/m²K
11

Insulation panel

U-value ≤ 1.5 W/m²K
12

Insulated door

U-value ≤ 1.2 W/m²K

The requirements for surface area and insulation values are specified in the “ Requirements ” (Guidelines for Energy-Efficient Housing) for the ISDE subsidy. The requirements for the ISDE subsidy are therefore the guiding principleshttps://www.rvo.nl/subsidies-financiering/isde/woningeigenaren/isolatiemaatregelen#Requirements-insulation 

You can receive a grant to cover all costs necessary for implementing the energy-saving measure(s). For example, insulation materials, labor costs for the contractor, and finishing materials such as drywall and paint/plaster.

*The higher the Rd value, the better the insulation. The lower the U-value, the better the insulation.
 

Version 2: For owner-occupied homes that are designated historic landmarks

1Energy-saving measuresMinimum number ofsquare meters Minimum Rd value or maximum U-value*Comments 
2

Cavity wall insulation

10m²

Rd value ≥ 1.1m² K/W 
3

Façade insulation

10m²

Rd value ≥ 2.5m² K/W 
4

Roof insulation

20m²

Rd value ≥ 2.5m² K/W 
5

Attic/loft Floor Insulation

20m²

Rd value ≥ 2.5m² K/W 
6

Floor Insulation

20m²

Rd value ≥ 3.5m² K/W 
7

Floor Insulation

20m²

Rd value ≥ 3.5m² K/W 
8Front or rear glazing

3m²

U-value of glass ≤ 3.0W/m²Kif the measure is implemented by January 1, 2026 

U-value of glass ≤ 5.8W/m²Kif the measure is implemented as of January 1, 2026

May be used as a replacement for or addition to glass (window) surfaces, frame panels, or doors
9Insulated window frame panels 

Panel U-value ≤ 2.0W/m²Kif the measure is implemented by January 1, 2026

Panel U-value ≤ 3.0W/m²Kif the measure is implemented on or after January 1, 2026

 
10

Insulated door

Door U-value ≤ 2.0W/m²K 

*The higher the Rd value, the better the insulation. The lower the U-value, the better the insulation.

Ventilation Measures for All Types of Owner-Occupied Homes

1Ventilation measure

Minimum return

Minimum ventilation capacity

2

Central CO2-Controlled Exhaust Fan

At least 2 CO2 sensors

125 m³/h

3

Central balanced ventilation with heat recovery (heat recovery unit)

85%

125 m³/h

4

Decentralized balanced ventilation with heat recovery (heat recovery unit)

80%

80 m³/h